/api/aoip/general-range

Use the interface to obtain value ranges of general settings.

Request Mode

POST /api/aoip/general-range

Response Body

{
    "tx-sample-rate": [
        "44100",
        "48000",
        "88200",
        "96000"
    ],
    "unbld-in": [
        "+12dBu",
        "+4dBu",
        "0dBu",
        "-2dBu",
        "0dBV",
        "-10dBV"
    ],
    "unbld-out": [
        "+12dBu",
        "+4dBu",
        "0dBu",
        "-2dBu",
        "0dBV",
        "-10dBV"
    ],
    "bld-in": [
        "+24dBu",
        "+18dBu",
        "+4dBu",
        "0dBu",
        "-2dBV",
        "0dBV",
        "-10dBV"
    ],
    "bld-out": [
        "+18dBu",
        "+4dBu",
        "0dBu",
        "-2dBV",
        "0dBV",
        "-10dBV"
    ],
    "igmp": [
        "Auto",
        "IGMPv2",
        "IGMPv3"
    ],
    "audio-pattern": [
        "off",
        "input",
        "output"
    ],
    "uac-num-channels": [
        "4",
        "2"
    ],
    "status": 0
}
Name Description
status 0 indicates that the request was accepted successfully. Refer to API Status Codes.